If I change the registry settings as you mentioned above (which I discovered independently in much the same matter as you) my deployment finishes without any problems whatsoever. You have them in the following objects: - TimeZone You can change it in your CUSTOMSETTINGS.INI, remove the quotes around the 035 value as well. About Advertising Privacy Terms Help Sitemap × Join millions of IT pros like you Log in to Spiceworks Reset community password Agree to Terms of Service Connect with Or Sign up Help Desk » Inventory » Monitor » Community » Home Error in unattend.xml - regarding Windows 7 sysprep by utsec.net on May 22, 2012 at 3:56 UTC | Windows 7 Power

Windows Setup log files are available in the following directories:   Log file location Description $windows.~bt\Sources\Panther Log location before Setup can access the drive. $windows.~bt\Sources\Rollback Log location when Setup rolls back in A component or setting specified in the answer file does not exist. If you are experiencing problems installing Windows, refer to the log files to troubleshoot the installation. I've saved the unattend.xml and looked for errors- going as far as to install an x86 Win7 virtual machine to validate the unattend.xml file in WISM.

Windows Could Not Parse Or Process Unattend Answer File For Pass Specialize

Appreciate your guidance. Thursday, September 11, 2014 10:38 AM Reply | Quote 2 Sign in to vote I had the same issue and deleting the "amd64_Microsoft-Windows-IE-InternetExplorer_nautral" (under: 4 specialize)solved my problem. I can't imagine we're the only two people who have seen this. For Windows 8 content, see Windows Deployment with the Windows ADK. OK, I've had to image a few more computers so I thought I would revisit this.  @Khaosus - There were no other user profiles other than the default administrator.  Neither were

You may get a better answer to your question by starting a new discussion. Then I'll let you know the results. In MDT 2010, there are many log files, but the major log file is BDD.log; it contains information from most of the other log files in MDT. Windows Could Not Parse Or Process Unattend Answer File The Specified File Does Not Exist Created a standard task and added 2 nodes      -Inject Drivers      -Install Application I've gotten past the endless installer failed screen by doing the following: Press SHIFT+F10 to open a

I had used this old guide to start using WDS, and quickly realized that I should roll updates into my reference image. Windows 10 Setup Log Files Maybe this is the cause of your error. it resolved my issue. Originally I prepared a master image win7 32bit and ran sysprep,generalize, shutdown options before creating ghost image. After that windows went to error recovery state with error https://technet.microsoft.com/en-us/windows/hh126389.aspx To Export the log to a file From the command line, use the Wevtutil or Tracerpt commands to save the log to an .xml or text file.

Thanks for answering! 0 Pimiento OP ChrisMort May 17, 2013 at 10:52 UTC 1st Post I too have the same error message when deploying machines and on the Windows 10 Setup Log Files Location The settings specified in the answer file cannot be applied. I never figured out why I got that error. 0 Pimiento OP ChrisMCooper Apr 9, 2013 at 2:17 UTC Aww, damn. By creating an account, you're agreeing to our Terms of Use and our Privacy Policy Not a member?

  • This two-part Experts Exchange video Micro Tutorial s… Windows 10 Windows 7 Windows 8 Windows OS MS Legacy OS Advertise Here Other articles by this author How to customize a default
  • Go to the properties of this task sequence.
  • A component or setting specified in the answer file does not exist.] 2013-03-27 17:39:06, Info This installation is blocked from completing due to compliance failures or invalid input; this is not
  • From the command line, type: Copy cscript :\sources\etwproviders\etwproviderinstall.vbs install :\sources\etwproviders Where is the drive letter of the Windows DVD media.
  • For information about using these tools, see the command-line Help.
  • The IEWelcomeMsg was at fault.
  • Wednesday, May 20, 2015 11:46 PM Reply | Quote 0 Sign in to vote A couple years after the fact.....but THANK YOU!!!!

Windows 10 Setup Log Files

Thanks! http://www.sevenforums.com/system-security/194885-c-windows-panther-what-directory-virus-mal-spamware.html Will I need to do this fix for that as well? Windows Could Not Parse Or Process Unattend Answer File For Pass Specialize Subscribe Posts Atom Posts Comments Atom Comments Most Popular Posts Kyocera Command Center default admin password Sending out Wireless Settings via GPO with Key Brother HL-5350DN reset and default web admin Windows Installation Log File Location have you tried using WSIM (Windows System Image Manager) a GUI tool to build the file? 0 Datil OP utsec.net May 22, 2012 at 6:26 UTC Power Users,

After reviewing logs and xml files over and over I didn't find anything that would even remotely think to change that settings. For more information about using the Event Viewer, see this Microsoft Web site. This article was published on May 13, 2010.Background – the Windows 7 setup engineBoth WDS and MDT 2010 are using Windows 7 Setup Engine (setup.exe) to deploy the Windows 7 image, There are separate keys for Windows 32 and 64-bit systems, as well as different keys for Windows Professional and Enterprise. Windows 10 Install Log Location

This errorindicates aproblemwith the information in the unattend.xml file, and tells youto checkthe “specialize” pass, in the “Microsoft-Windows-Shell-Setup” container. Wednesday, May 20, 2015 8:25 PM Reply | Quote 0 Sign in to vote In my experience only had to remove the IEWelcomeMSg from the unattend whenimaging Windows 7 via MDT they must have changed something since then.   EDIT: I found the solution: http://social.technet.microsoft.com/Forums/en-US/mdt/thread/662cc248-1053-453a-9a95-d1705c246d18

  the problem is that ie10 bails on this one particular setting which wds seems to put Windows® Setup creates log files for all actions that take place during installation.

This was also happening to me on the capture task as well.ReplyDeleteAnonymous17 September 2013 at 07:28Thank you! Windows 10 Setup Error Log Works a treat thank you so much, it's been driving us insane!!Gotta love step by step solutions. A component or setting specified in the answer file does not exist. 2013-03-27 17:39:06, Error [0x0600c2] IBS Callback_Unattend_InitEngine:An error occurred while finding/loading the unattend file; hr = 0x1, hrResult = 0x80220001[gle=0x00000490]

Good to know!) with no luck.

For example, if setup fails very early in the process, before setup even created the partition on which to deploy Windows 7, you will find the log file in the Windows Retry the operation from an x86 operating system"ReplyDeleteRepliesMarc Hundley14 November 2013 at 21:00That is correct Brad, in order to create a catalog for an x86 wim you will need to add I've saved the unattend.xml and looked for errors- going as far as to install an x86 Win7 virtual machine to validate the unattend.xml file in WISM Other information that might be Windows 10 Installation Log File Location Specfically, look in this section: There are normally only three tags in that area: ComputerName (set as * in the OS layer, and edited to

One type of workstation is not working. Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL Join the community Back I agree Powerful tools you need, all for free. Chose my "Sysprep and Capture" task.

I cant imagine the issue being due to an OEM ver of Windows but who knows with MS these days. 0 Pimiento OP Lucas1879 Oct 29, 2012 at Fix [SOLVED] Actually simple, but only if you know where to look and since you've probably scrolled down andignored everything I said above, I'll get to the point, follow these instructions: Text Quote Post |Replace Attachment Add link Text to display: Where should this link go? Join and Comment By clicking you are agreeing to Experts Exchange's Terms of Use.

I even tried verifying my unattend file with WISM and got the same deprecation issue. Here was the problem in my case when I ran into this error: The hostname defined in specialized section of the unattend file was too long. A component or setting specified in the answer file does not exist." Alternatively, you've just made a new MDT Task Sequence and slipstreamed updates into it and received the same error. Evans at 10:32 Email ThisBlogThis!Share to TwitterShare to FacebookShare to Pinterest Labels: 2012, ADK, C:\windows\panther\unattend.xml, infinite loop, MDT, Server 2012, unattend.xml, Windows 7 33 comments: James Hogg2 August 2013 at 16:34Thanks

The error was detected while processing settings for component [Microsoft-Windows-Shell-Setup]. There is also a setupact.err log file that only contains error messages from the setup. Posted by D. But it did not carry on doing the unattended install, which wasn't a massive issue.

If so, I'd be very interested in hearing what you were able to do. C:\Windows\Panther\Unattend.xml Error (described above) Reasons The cause of this is simple, it's internet explorer 10.0 whichyou have installed either within the image or slipstreamed into the image. I got the dreaded Text"Windows could not parse or process unattend answer file [C:\windows\Panther\unattend.xml] for pass [specialize]. Unless TimeZone is bad, this error almost always means that the selected ProductKey is wrong.

Right click on IEWelcomeMsg and delete this component: 4. Try Free For 30 Days Join & Write a Comment Already a member? Make sure your hostname is under 15 chars. - hostname Thursday, December 17, 2015 8:38 PM Reply | Quote 1 Sign in to vote Kevin, you're spot on. I didn't try to copy user profiles/settings/migrate etc I imported the captured image to WDT.